  1. PDW125

    Air source Heat Pumps any good?

    agreed with everything you said until you got to that point ..!! If it is a sealed unvented cylinder then the legionella risk is nil. Legionella requires air entry to the system along with moisture. It will not grow in a closed chlorinated water source and there are no reported cases anywhere of...
  2. PDW125

    Is pressurised hot water worth it, with oil?

    Wrong thread
  3. PDW125

    Air source Heat Pumps any good?

    If it is an unvented cylinder - ie one with no header tank and at mains pressure - it is not required. Get it turned off
  4. PDW125

    Boiler change!!

    Also remember that the glycol mix in GSHP needs replacing between 5-7 years as it degrades. It’s not a cheap job and it’s sometimes missed in the cost of ownership.
  5. PDW125

    Boiler change!!

    That isn’t strictly true - efficiency is irrelevant, and the sizing issue affects all heating systems including oil and gas boilers. A poorly designed system in a badly insulated property will use more energy in any event. An oversized ASHP will happily keep a building warm but it won’t do it...
  6. PDW125

    Boiler change!!

    About 53 years was the last estimate.
  7. PDW125

    Boiler change!!

    Massive amounts of research has been done and then new heat pumps running R410a have addressed a lot of the old issues. Inverter drive pumps have replaced the old high power scroll pumps (ie the old refrigeration technology), controls with weather compensation, CoP moving from 2.5 at A7W35 to...
  8. PDW125

    18mm or 12mm plywood - carcassing.

    Worth checking Facebook marketplace for offcuts - I picked up this lot which is the equivalent of 4 full boards of 18mm, a sheet of 12mm and 2 sheets of 5.5mm for £65.. all are 1220mm wide, with variation from 750-1100mm on depth. That is all going into wall and base cabinets.
  9. PDW125

    Axminster nailer connector to airline

    Airline and compressor are fitted with older PCL fittings. Nut on the airline looks to be 1/4 BSP or taper, just remove that and fit the top right fitting with a bit of PTFE tape from this kit. Sukudon 10 pcs Air Line Connectors Euro Airline Hose Compressor Fittings 1/4" BSP Air Coupler and...
  10. PDW125

    MFT tops

    If you went for standard board sizes (1200 x 600 for example) then you could set up that there was a drill pattern that could just include or exclude certain rows or columns. CNC machine time would be your only variable, or the additional wear cost on bits for each hole drilled. At that point...
  11. PDW125

    Introducing WorkshopBuddy

    Found this useful when I was doing some layout work on odd stock but .. it’s got one thing missing that I can’t see on the mobile version - duplicating parts ! If I want 8 No. 450x545 I have to enter each one on the list. Sometimes I will use a mobile and send to print PDF so it’s a really...
  12. PDW125

    Finding a square square..

    I bought something similar from Chronos for £24 - just in a plastic box ! https://www.chronos.ltd.uk/product/set-of-engineers-squares/
  13. PDW125

    Finding a square square..

    Thanks @steve355 I had forgotten about chronos so my wallet is now much lighter for the things I needed, and a few things I just wanted …..
  14. PDW125

    Finding a square square..

    Looking for an engineers square that is - as the title says - square, to use a reference for the rest of my tools. Recently found out my sliding square is out, and there’s no way I would trust my framing squares for setting up saws so where does everyone get their engineers squares from ...
  15. PDW125

    Newbie + a question

    Sounds like shorting in the capacitor or one of the rotor/stator windings. Could also be rubbish in the back of the motor if it’s an open frame - seen that where something shorts the motor when it spins and centrifugal force throws it outwards.
  16. PDW125

    Base for Pizza Oven - Will it be strong enough

    The base will possibly need to support the whole of the oven and not just the edges - assuming it’s a cast refractory one, they normally recommend building something with one or two concrete lintels across the centre.
  17. PDW125

    Heating in a garden room???

    Cheap air to air AC unit. Can cool as well as heat and you can get them for about £500 pre-charged so no F-Gas cert required.
  18. PDW125

    Connection problems

    OK so you need to constantly check the router - the EE ones have a technical settings and technical log which records the issues and more importantly the recorded line speeds and jitter/noise. Firstly - you need to call EE weekly. And be persistent. They will rob you off (especially offshore...
  19. PDW125

    Mini compressor - Senco 5ltr, 0.5hp

    Just for info - the Hyundai eBay store is part of the 10% off til June 30th with Save-10-today as the code. Makes the A graded 8 litre compressors change of £100 delivered.
  20. PDW125

    Garden Room - Steel Beam Help Please!!

    Quick fag packet calculation and you could dispense with the steel and use 2 No. 220x45 laminated with an 8mm fitch plate and bolted at 400mm centres across the full width of the 5m span. On the bottom of this add in a 95x45 on flat to give a total height of 315mm from the top of the bifold to...
Top